Can times to first token from two load tools be compared?
No: each load tool starts and stops its first-token stopwatch at its own point, so a time to first token from one tool is not comparable with one from another. pairbench reads each tool’s own value and names the tool and version beside it.
Compare first-token times only between runs measured by the same tool, at the same version,
with the same request settings. pairbench does not refuse other comparisons: a result file
side may name its own driver (format), so two sides of one experiment can be read by two
different tools. The results then name the driver and tool version of each side
(sides[].driver), the reports say which driver read which side, and the comparison carries
the loud note drivers_differ: its ratio compares the two tools as well as the two sides.
The descriptions below are read from each tool’s public source at the version stated. A later version may change them; the driver records the version of every launch.
GuideLLM 0.8.1
Section titled “GuideLLM 0.8.1”Source: schemas/base/request_stats.py
and backends/openai/http.py.
- Formula:
time_to_first_token_ms = 1000 * (first_token_iteration - request_start). - Start:
request_startis the wall-clock time (time.time()) at which the HTTP client starts writing the request headers, taken from a trace hook of the client. It is first set just before the streaming request is opened, and the trace hook replaces it. - Stop:
first_token_iterationis the wall-clock time of the first streamed line that the request handler counts as one or more generated tokens. Reasoning tokens count; the time to the first non-reasoning token is a separate value. - Inter-token latency:
(last_token_iteration - first_token_iteration)divided by the output tokens less one, in milliseconds.
AIPerf 0.13.0
Section titled “AIPerf 0.13.0”Source: metrics/types/ttft_metric.py,
transports/aiohttp_client.py
and the metrics reference.
- Formula:
ttft_ns = content_responses[0].perf_ns - request.start_perf_ns. - Start:
start_perf_nsis a monotonic clock reading (time.perf_counter_ns()) taken after the client session is set up and immediately before the request is issued, so a connection that has to be opened falls inside the interval. - Stop: the receive time of the first streamed message with non-empty content.
- Scope: the metrics reference says the value includes network latency, queuing time, prompt processing and the generation of the first token or chunk of tokens.
vLLM benchmark client (vllm bench serve), v0.33.0
Section titled “vLLM benchmark client (vllm bench serve), v0.33.0”Source: benchmarks/lib/endpoint_request_func.py.
- Formula:
ttft = timestamp - st, in seconds. - Start:
stis a monotonic clock reading (time.perf_counter()) taken just before the POST request is issued. - Stop: for the completions endpoint, the first server-sent data message that holds
choices, even when its text is empty, for example for special tokens; the clock is read after the message is parsed. For the chat completions endpoint, the first data message whose first choice carries streamed output; the clock is read before the message is parsed. Comment lines, which servers send as pings, are skipped. - Inter-token latency: the list of gaps between consecutive such messages.
pairbench reads the saved result file of the vLLM client. Its vllm-bench driver is marked
experimental until it has a fixture from a real run.
What differs
Section titled “What differs”| GuideLLM 0.8.1 | AIPerf 0.13.0 | vLLM client v0.33.0 | |
|---|---|---|---|
| clock | wall clock | monotonic | monotonic |
| start | first header write | before the request is issued | before the POST is issued |
| stop | first line with a counted token | first message with non-empty content | first message with choices (completions) or streamed output (chat) |
A difference in where the clock starts or stops is a constant added to every request. It moves a ratio toward 1 and changes an absolute value; pairbench’s paired comparison of two server versions with one tool is still sound, but a first-token time quoted next to a number from another tool is not.